Hires

Large

Default

Tablet Portait

Handheld Landscape

Handheld Portait

William Harris
Robert Turner High School

ID #
334-904384
Witness
John Hunter Morgan
Tested
December 08, 2021
Certified
May 02, 2022

Welder Qualification Test Record

Qualification Type
AWS D9.1 Welder Qualification

WPS
AWS 1-GMAW-S
PQR
Prequalified

Qualification Test Performed
> 70% Score Written Knowledge Test
Not Reported
Welding Process and Electrode Tested with
GMAW-S, ER70S-6
Metal Type/Condition
Steel, Uncoated
Groove Weld Test Position/Backing
N/A
Fillet Weld Test Position
4F
Test Metal Thickness
11 ga. (0.120 in.)
Shielding Gas
75% Ar/25%CO2

Essential Variables Qualified By Test
Types of Base Metal Qualified
Uncoated Steel < 0.30% C, 0.50% Cr
Welding Process Qualified
GMAW-S, Semi Auto
Filler Metal F-Number Qualified
F-6
Welding Current Qualified for Use
DCEP
Production Positions Qualified For Use
1F, 2F, 3F Down, 4F
Metal Thickness Range Qualified For Use
16 ga. (0.062 in.) to 3 ga. (0.239 in.)

Visual Inspection Results
Complete Weld Joint Fusion and Penetration
Acceptable
Groove Weld Face Reinforcement < 1/8 in.
N/A
Required minimum throat size
Acceptable
Weld convexity < 1/8 in.
Acceptable
Porosity located in the weld is < 1/32 in.
Acceptable*
Undercut is less than < 1/32 in.
Acceptable*
Base Metal, Weld, HAZ, cracking
Acceptable
 
*Based on min. 1/8 in. metal thickness

We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, joined, and examined in accordance with the requirements of AWS D9.1 Sheet Metal Welding Code.
Approved By
Richard J DePue
Organization
CWT Co.
Qualifications
SCWI, Test Supervisor
License Stamp
License
#03010018

Supplementary Information

  1. Welders are only qualified to weld on the thicknesses and diameters listed above.
  2. Welders are only qualified to weld in the positions listed above.
  3. Qualification on groove welds will qualify a welder to make groove and fillet welds.
  4. Qualification of fillet welds will only qualify a welder to make fillet welds.
  5. Welders are only qualified to weld the types of metals listed.
  6. A welder must be able to produce their updated log sheet anytime their certification is questioned.
  7. Structural welders are not qualified to make welds on pressurized components.
  8. Always make sure base and filler metals are clean and free of slag, scale, rust, oil, paint or other foreign materials.
  9. Oxy-fuel and plasma cut surfaces must be ground before welding to remove slag, oxides and heat affected zone.
  10. Base metals shall be preheated when surface temperature is below 32°F and recommended when surface is below 70°F.
  11. A welder is only qualified to use the electrodes identified above.
  12. Low hydrogen electrodes, F-4 (7018 and any ending in 5, 6, 8):
    • Must be stored in a heated vented oven at 250°F.
    • Cannot be exposed to the atmosphere for time periods exceeding 4 hours.
    • Must be purchased in a sealed container.
    • Cannot be used if damaged or wet.
  13. All other electrodes:
    • Must be kept dry.
    • Cannot be used if damaged or wet.
    • Should not be stored in an electrode oven with low hydrogen electrodes.
  14. For AWS D1.1, ASME IX and API 1104 codes, a welder's qualification/certification will expire in 6 months unless continuity is demonstrated. An AWS D9.1 qualification will extend to 12 months. In all cases, if continuity is demonstrated using the process, qualification/certification will extend indefinitely.

William Harris
Robert Turner High School

ID #
334-904384
Witness
John Hunter Morgan
Tested
January 10, 2022
Certified
May 02, 2022

Welder Qualification Test Record

Qualification Type
Tack Welder

WPS
TX-ED-WP6 Rev. 4
PQR
TX-PQ-GT-03


Description of Variable

Actual Values
Used in Weld Test
Permitted Qualifications Range

Welding Process
GTAW
GTAW
Welding Current & Polarity
DCEN
DCEN
Welding Position
1F, 2F, 3F Tacks
1F, 2F, 3F Tacks
Welding Progression (up or down)
Up
Up
Weld Backing Used (grooves)
N/A
N/A
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
N/A
Not permitted
Plate Thickness - Fillet
Tack welded steel 1/2" Thick
Tacking steel 1/8" - Unlimited
Pipe Wall Thickness - Groove
N/A
Not permitted
Pipe Wall Thickness - Fillet
N/A
Tacking steel 1/8" - Unlimited
Pipe Outside Diameter - Groove
N/A
Not permitted
Pipe Outside Diameter - Fillet
N/A
Tacking pipe with fillet welds
Weld deposit thickness
Single Pass
Single Pass
Filler Metal - Specification #
AWS A5.18
AWS A5.18
Filler Metal - Classification #
ER70S-6
ER70S-X
Filler Metal - F #
F-6
F-6
GTAW Electrode - Specification #
AWS A5.12
AWS A5.12
GTAW Electrode - Classification #
EWLa-2
EWLa-2
Shielding & Gas Composition.
Argon
Argon
Visual Inspection
  • Acceptable: Yes
  • Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Radiographic Test
  • Film ID #'s: N/A
Guided Bend Test
  • Face Bends Acceptable: N/A
  • Root Bends Acceptable: N/A
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
  • Weld Appearance: Acceptable
  • Fillet Weld Size: 1/4"
  • Fractured Root: Acceptable
  • Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.1: 2020 Structural Steel Welding Code.
Approved By
Richard J DePue
Organization
CWT Co.
Qualifications
SCWI, Test Supervisor
License Stamp
License
#03010018

Supplementary Information

  1. Welders are only qualified to weld on the thicknesses and diameters listed above.
  2. Welders are only qualified to weld in the positions listed above.
  3. Qualification on groove welds will qualify a welder to make groove and fillet welds.
  4. Qualification of fillet welds will only qualify a welder to make fillet welds.
  5. Welders are only qualified to weld the types of metals listed.
  6. A welder must be able to produce their updated log sheet anytime their certification is questioned.
  7. Structural welders are not qualified to make welds on pressurized components.
  8. Always make sure base and filler metals are clean and free of slag, scale, rust, oil, paint or other foreign materials.
  9. Oxy-fuel and plasma cut surfaces must be ground before welding to remove slag, oxides and heat affected zone.
  10. Base metals shall be preheated when surface temperature is below 32°F and recommended when surface is below 70°F.
  11. A welder is only qualified to use the electrodes identified above.
  12. Low hydrogen electrodes, F-4 (7018 and any ending in 5, 6, 8):
    • Must be stored in a heated vented oven at 250°F.
    • Cannot be exposed to the atmosphere for time periods exceeding 4 hours.
    • Must be purchased in a sealed container.
    • Cannot be used if damaged or wet.
  13. All other electrodes:
    • Must be kept dry.
    • Cannot be used if damaged or wet.
    • Should not be stored in an electrode oven with low hydrogen electrodes.
  14. For AWS D1.1, ASME IX and API 1104 codes, a welder's qualification/certification will expire in 6 months unless continuity is demonstrated. An AWS D9.1 qualification will extend to 12 months. In all cases, if continuity is demonstrated using the process, qualification/certification will extend indefinitely.

William Harris
Robert Turner High School

ID #
334-904384
Witness
Hunter Morgan
Tested
December 17, 2020
Certified
March 29, 2021

Welder Qualification Test Record

Qualification Type
Tack Welder

WPS
TX-ED-WP1 Rev. 4
PQR
TX-PQ-SM-03


Description of Variable

Actual Values
Used in Weld Test
Permitted Qualifications Range

Welding Process
SMAW
SMAW
Welding Current & Polarity
DCEP
AC or DC
Welding Position
1F, 2F, 3F, 4F Tacks
1F, 2F, 3F, 4F Tacks
Welding Progression (up or down)
Up
Up
Weld Backing Used (grooves)
N/A
N/A
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
N/A
Not permitted
Plate Thickness - Fillet
Tack welded steel 1/2" Thick
Tacking steel 1/8" - Unlimited
Pipe Wall Thickness - Groove
N/A
Not permitted
Pipe Wall Thickness - Fillet
N/A
Tacking steel 1/8" - Unlimited
Pipe Outside Diameter - Groove
N/A
N/A
Pipe Outside Diameter - Fillet
N/A
Tacking pipe with fillet welds
Weld deposit thickness
Single Pass
Single Pass
Filler Metal - Specification #
AWS A5.1
AWS 5.1
Filler Metal - Classification #
E7018
E70XX, E60XX
Filler Metal - F #
F-4
F-1 to 4
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
N/A
N/A
Visual Inspection
  • Acceptable: Yes
  • Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Radiographic Test
  • Film ID #'s: N/A
Guided Bend Test
  • Face Bends Acceptable: N/A
  • Root Bends Acceptable: N/A
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
  • Weld Appearance: Acceptable
  • Fillet Weld Size: 1/4"
  • Fractured Root: Acceptable
  • Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.1: 2015 Structural Steel Welding Code.
Approved By
Richard J DePue
Organization
CWT Co.
Qualifications
SCWI, Test Supervisor
License Stamp
License
#03010018

Supplementary Information

  1. Welders are only qualified to weld on the thicknesses and diameters listed above.
  2. Welders are only qualified to weld in the positions listed above.
  3. Qualification on groove welds will qualify a welder to make groove and fillet welds.
  4. Qualification of fillet welds will only qualify a welder to make fillet welds.
  5. Welders are only qualified to weld the types of metals listed.
  6. A welder must be able to produce their updated log sheet anytime their certification is questioned.
  7. Structural welders are not qualified to make welds on pressurized components.
  8. Always make sure base and filler metals are clean and free of slag, scale, rust, oil, paint or other foreign materials.
  9. Oxy-fuel and plasma cut surfaces must be ground before welding to remove slag, oxides and heat affected zone.
  10. Base metals shall be preheated when surface temperature is below 32°F and recommended when surface is below 70°F.
  11. A welder is only qualified to use the electrodes identified above.
  12. Low hydrogen electrodes, F-4 (7018 and any ending in 5, 6, 8):
    • Must be stored in a heated vented oven at 250°F.
    • Cannot be exposed to the atmosphere for time periods exceeding 4 hours.
    • Must be purchased in a sealed container.
    • Cannot be used if damaged or wet.
  13. All other electrodes:
    • Must be kept dry.
    • Cannot be used if damaged or wet.
    • Should not be stored in an electrode oven with low hydrogen electrodes.
  14. For AWS D1.1, ASME IX and API 1104 codes, a welder's qualification/certification will expire in 6 months unless continuity is demonstrated. An AWS D9.1 qualification will extend to 12 months. In all cases, if continuity is demonstrated using the process, qualification/certification will extend indefinitely.

William Harris
Robert Turner High School

ID #
334-904384
Witness
Hunter Morgan
Tested
December 17, 2020
Certified
March 26, 2021

Welder Qualification Test Record

Qualification Type
Welder

WPS
TX-ED-WP7 Rev. 4
PQR
TX-PQ-GM-03


Description of Variable

Actual Values
Used in Weld Test
Permitted Qualifications Range

Welding Process
GMAW-S
GMAW-S
Welding Current & Polarity
DCEP
DCEP
Welding Position
3F, 4F
1F, 2F, 3F, 4F
Welding Progression (up or down)
Down
Down
Weld Backing Used (grooves)
N/A
N/A
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
N/A
N/A
Plate Thickness - Fillet
11ga (.120 in)
16ga (.062 in) to 3ga (.239 in)
Pipe Wall Thickness - Groove
N/A
N/A
Pipe Wall Thickness - Fillet
N/A
16ga (.062 in) to 3ga (.239 in)
Pipe Outside Diameter - Groove
N/A
N/A
Pipe Outside Diameter - Fillet
N/A
All pipe fillets
Weld deposit thickness
Single Pass Fillet
Single Pass Fillets
Filler Metal - Specification #
AWS A5.18
AWS 5.18
Filler Metal - Classification #
ER70S-6
ER70S-X
Filler Metal - F #
F-6
F-6
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
Ar/CO2
Ar/CO2
Visual Inspection
  • Acceptable: Yes
  • Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Radiographic Test
  • Film ID #'s: N/A
Guided Bend Test
  • Face Bends Acceptable: N/A
  • Root Bends Acceptable: N/A
  • Side Bends Acceptable: N/A
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
  • Weld Appearance: N/A
  • Fillet Weld Size: N/A
  • Fractured Root: N/A
  • Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D9.1: 2012 Sheet Metal Welding Code.
Approved By
Richard J DePue
Organization
CWT Co.
Qualifications
SCWI, Test Supervisor
License Stamp
License
#03010018

Supplementary Information

  1. Welders are only qualified to weld on the thicknesses and diameters listed above.
  2. Welders are only qualified to weld in the positions listed above.
  3. Qualification on groove welds will qualify a welder to make groove and fillet welds.
  4. Qualification of fillet welds will only qualify a welder to make fillet welds.
  5. Welders are only qualified to weld the types of metals listed.
  6. A welder must be able to produce their updated log sheet anytime their certification is questioned.
  7. Structural welders are not qualified to make welds on pressurized components.
  8. Always make sure base and filler metals are clean and free of slag, scale, rust, oil, paint or other foreign materials.
  9. Oxy-fuel and plasma cut surfaces must be ground before welding to remove slag, oxides and heat affected zone.
  10. Base metals shall be preheated when surface temperature is below 32°F and recommended when surface is below 70°F.
  11. A welder is only qualified to use the electrodes identified above.
  12. Low hydrogen electrodes, F-4 (7018 and any ending in 5, 6, 8):
    • Must be stored in a heated vented oven at 250°F.
    • Cannot be exposed to the atmosphere for time periods exceeding 4 hours.
    • Must be purchased in a sealed container.
    • Cannot be used if damaged or wet.
  13. All other electrodes:
    • Must be kept dry.
    • Cannot be used if damaged or wet.
    • Should not be stored in an electrode oven with low hydrogen electrodes.
  14. For AWS D1.1, ASME IX and API 1104 codes, a welder's qualification/certification will expire in 6 months unless continuity is demonstrated. An AWS D9.1 qualification will extend to 12 months. In all cases, if continuity is demonstrated using the process, qualification/certification will extend indefinitely.

William Harris
Robert Turner High School

ID #
334-904384
Witness
Rhonda Morgan
Tested
February 07, 2020
Certified
June 11, 2020

Welder Qualification Test Record

Qualification Type
Tack Welder

WPS
TX-ED-WP2 Rev. 4
PQR
TX-PQ-FC-03


Description of Variable

Actual Values
Used in Weld Test
Permitted Qualifications Range

Welding Process
FCAW
FCAW
Welding Current & Polarity
DCEP
DCEP
Welding Position
1F, 2F, 3F, 4F Tack
1F, 2F, 3F, 4F Tacks
Welding Progression (up or down)
Up
Up
Weld Backing Used (grooves)
N/A
N/A
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
N/A
Not permitted
Plate Thickness - Fillet
Tack welded steel 3/8" Thick
Tacking steel 1/8" - 3/8"
Pipe Wall Thickness - Groove
N/A
Not permitted
Pipe Wall Thickness - Fillet
N/A
Tacking steel 1/8" - 3/8"
Pipe Outside Diameter - Groove
N/A
N/A
Pipe Outside Diameter - Fillet
N/A
Tacking pipe with fillet welds
Weld deposit thickness
Single Pass
Single Pass
Filler Metal - Specification #
AWS A5.20
AWS 5.20
Filler Metal - Classification #
E71T-1
E71T-X
Filler Metal - F #
F-6
F-6
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
Ar/CO2
Ar/CO2
Visual Inspection
  • Acceptable: Yes
  • Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Radiographic Test
  • Film ID #'s: N/A
Guided Bend Test
  • Face Bends Acceptable: N/A
  • Root Bends Acceptable: N/A
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
  • Weld Appearance: Acceptable
  • Fillet Weld Size: 1/4"
  • Fractured Root: Acceptable
  • Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.1: 2015 Structural Steel Welding Code.
Approved By
Richard J DePue
Organization
CWT Co.
Qualifications
SCWI, Test Supervisor
License Stamp
License
#03010018

Supplementary Information

  1. Welders are only qualified to weld on the thicknesses and diameters listed above.
  2. Welders are only qualified to weld in the positions listed above.
  3. Qualification on groove welds will qualify a welder to make groove and fillet welds.
  4. Qualification of fillet welds will only qualify a welder to make fillet welds.
  5. Welders are only qualified to weld the types of metals listed.
  6. A welder must be able to produce their updated log sheet anytime their certification is questioned.
  7. Structural welders are not qualified to make welds on pressurized components.
  8. Always make sure base and filler metals are clean and free of slag, scale, rust, oil, paint or other foreign materials.
  9. Oxy-fuel and plasma cut surfaces must be ground before welding to remove slag, oxides and heat affected zone.
  10. Base metals shall be preheated when surface temperature is below 32°F and recommended when surface is below 70°F.
  11. A welder is only qualified to use the electrodes identified above.
  12. Low hydrogen electrodes, F-4 (7018 and any ending in 5, 6, 8):
    • Must be stored in a heated vented oven at 250°F.
    • Cannot be exposed to the atmosphere for time periods exceeding 4 hours.
    • Must be purchased in a sealed container.
    • Cannot be used if damaged or wet.
  13. All other electrodes:
    • Must be kept dry.
    • Cannot be used if damaged or wet.
    • Should not be stored in an electrode oven with low hydrogen electrodes.
  14. For AWS D1.1, ASME IX and API 1104 codes, a welder's qualification/certification will expire in 6 months unless continuity is demonstrated. An AWS D9.1 qualification will extend to 12 months. In all cases, if continuity is demonstrated using the process, qualification/certification will extend indefinitely.

William Harris
Robert Turner High School

ID #
334-904384
Witness
Rhonda Morgan
Tested
February 07, 2020
Certified
June 11, 2020

Welder Qualification Test Record

Qualification Type
Welder

WPS
TX-ED-WP2 Rev. 4
PQR
TX-PQ-FC-03


Description of Variable

Actual Values
Used in Weld Test
Permitted Qualifications Range

Welding Process
FCAW
FCAW
Welding Current & Polarity
DCEP
DCEP
Welding Position
3F, 4F
1F, 2F, 3F, 4F
Welding Progression (up or down)
Up
Up
Weld Backing Used (grooves)
N/A
N/A
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
N/A
N/A
Plate Thickness - Fillet
3ga (.239 in)
11ga (.120 in) to 3ga (.239 in)
Pipe Wall Thickness - Groove
N/A
N/A
Pipe Wall Thickness - Fillet
N/A
11ga (.120 in) to 3ga (.239 in)
Pipe Outside Diameter - Groove
N/A
N/A
Pipe Outside Diameter - Fillet
N/A
All pipe fillets
Weld deposit thickness
Single and Multi-Pass Fillets
Single and Multi-Pass Fillets
Filler Metal - Specification #
AWS A5.20
AWS 5.20
Filler Metal - Classification #
E71T-1
E71T-X
Filler Metal - F #
F-6
F-6
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
Ar/CO2
Ar/CO2
Visual Inspection
  • Acceptable: Yes
  • Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Radiographic Test
  • Film ID #'s: N/A
Guided Bend Test
  • Face Bends Acceptable: N/A
  • Root Bends Acceptable: N/A
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
  • Weld Appearance: N/A
  • Fillet Weld Size: N/A
  • Fractured Root: N/A
  • Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D9.1: 2012 Sheet Metal Welding Code.
Approved By
Richard J DePue
Organization
CWT Co.
Qualifications
SCWI, Test Supervisor
License Stamp
License
#03010018

Supplementary Information

  1. Welders are only qualified to weld on the thicknesses and diameters listed above.
  2. Welders are only qualified to weld in the positions listed above.
  3. Qualification on groove welds will qualify a welder to make groove and fillet welds.
  4. Qualification of fillet welds will only qualify a welder to make fillet welds.
  5. Welders are only qualified to weld the types of metals listed.
  6. A welder must be able to produce their updated log sheet anytime their certification is questioned.
  7. Structural welders are not qualified to make welds on pressurized components.
  8. Always make sure base and filler metals are clean and free of slag, scale, rust, oil, paint or other foreign materials.
  9. Oxy-fuel and plasma cut surfaces must be ground before welding to remove slag, oxides and heat affected zone.
  10. Base metals shall be preheated when surface temperature is below 32°F and recommended when surface is below 70°F.
  11. A welder is only qualified to use the electrodes identified above.
  12. Low hydrogen electrodes, F-4 (7018 and any ending in 5, 6, 8):
    • Must be stored in a heated vented oven at 250°F.
    • Cannot be exposed to the atmosphere for time periods exceeding 4 hours.
    • Must be purchased in a sealed container.
    • Cannot be used if damaged or wet.
  13. All other electrodes:
    • Must be kept dry.
    • Cannot be used if damaged or wet.
    • Should not be stored in an electrode oven with low hydrogen electrodes.
  14. For AWS D1.1, ASME IX and API 1104 codes, a welder's qualification/certification will expire in 6 months unless continuity is demonstrated. An AWS D9.1 qualification will extend to 12 months. In all cases, if continuity is demonstrated using the process, qualification/certification will extend indefinitely.