Ben Gonzalez
Certified Welding and Testing
Certified
January 20, 2023
Welder Qualification Test Record
Qualification Type
Welder
Actual Values
Used in Weld Test
Permitted Qualifications Range
Welding Process
GMAW-S Root, FCAW Fill/Cap
GMAW-S Root, FCAW Fill/Cap
Welding Current & Polarity
DCEP
DCEP
Welding Position
3G
1F, 2F, 3F, 1G, 2G, 3G
Welding Progression (up or down)
Up
Up
Weld Backing Used (grooves)
None
With or without backing
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
3/8"
1/8" to 3/4"
Plate Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Wall Thickness - Groove
N/A
1/8" to 3/4"
Pipe Wall Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Outside Diameter - Groove
N/A
> 24" Only
Pipe Outside Diameter - Fillet
N/A
All pipe fillets
Weld deposit thickness
1/8" per pass
1/8" per pass
Filler Metal - Specification #
AWS A5.18/5.20
AWS A5.18/5.20
Filler Metal - Classification #
ER70S-6, E71T-1
ER70S-6, E71T-1
Filler Metal - F #
F-6
F-6
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
Ar/CO2
Ar/CO2
Visual Inspection
- Acceptable: Yes
- Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Guided Bend Test
- Face Bends Acceptable: Acceptable
- Root Bends Acceptable: Acceptable
- Side Bends Acceptable: N/A
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
- Weld Appearance: N/A
- Fillet Weld Size: N/A
- Fractured Root: N/A
- Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.1: 2015 Structural Steel Welding Code.
Approved By
Richard J DePue
Qualifications
SCWI, Test Supervisor
License
#03010018
Ben Gonzalez
Certified Welding and Testing
Certified
February 11, 2019
Welder Qualification Test Record
Qualification Type
API/ASME Welder
Actual Values
Used in Weld Test
Permitted Qualifications Range
Welding Process
SMAW
SMAW
Welding Current & Polarity
DCEP
AC or DC
Welding Position
2F
1F, 2F
Welding Progression (up or down)
N/A
N/A
Weld Backing Used (QW-402)
N/A
N/A
Material Type (QW-403)
P-No. 1 to P-No. 1
P-No.1 to P-No.11
Plate Thickness - Groove
N/A
N/A
Plate Thickness - Fillet
3/8"
Unlimited
Pipe Wall Thickness - Groove
N/A
N/A
Pipe Wall Thickness - Fillet
N/A
Unlimited
Pipe Outside Diameter - Groove
N/A
N/A
Pipe Outside Diameter - Fillet
N/A
All pipe fillets
Weld deposit thickness
Single Pass
Single Pass
Filler Metal - Specification #
AWS A5.1
AWS 5.1
Filler Metal - Classification #
E7018
E70XX, E60XX
Filler Metal - F #
F-4
F-1 to 4
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
N/A
N/A
Visual Inspection
- Acceptable: Yes, QW-194
- Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Guided Bend Test
- Face Bends Acceptable: N/A
- Root Bends Acceptable: N/A
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
- Weld Appearance: Acceptable, QW-194
- Fillet Weld Size: 1/4"
- Fractured Root: Acceptable, QW-462
- Cross Section: Acceptable, QW-462
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
According to API 577, the herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of ASME BPV Code, Section lX.
Approved By
Richard J DePue
Qualifications
SCWI, Test Supervisor
License
#03010018
Ben Gonzalez
Certified Welding and Testing
Certified
February 11, 2019
Welder Qualification Test Record
Qualification Type
Tack Welder
Actual Values
Used in Weld Test
Permitted Qualifications Range
Welding Process
SMAW
SMAW
Welding Current & Polarity
DCEP
AC or DC
Welding Position
1F, 2F Tack
1F, 2F Tack
Welding Progression (up or down)
N/A
N/A
Weld Backing Used (grooves)
N/A
N/A
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
N/A
Not permitted
Plate Thickness - Fillet
Tack welded steel 1/2" Thick
Tacking steel 1/8" - Unlimited
Pipe Wall Thickness - Groove
N/A
Not permitted
Pipe Wall Thickness - Fillet
N/A
Tacking steel 1/8" - Unlimited
Pipe Outside Diameter - Groove
N/A
Any diameter
Pipe Outside Diameter - Fillet
N/A
Taking pipe with fillet welds
Weld deposit thickness
Single Pass
Single Pass
Filler Metal - Specification #
AWS A5.1
AWS 5.1
Filler Metal - Classification #
E7018
E70XX, E60XX
Filler Metal - F #
F-4
F-1 to 4
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
N/A
N/A
Visual Inspection
- Acceptable: Yes
- Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Guided Bend Test
- Face Bends Acceptable: N/A
- Root Bends Acceptable: N/A
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
- Weld Appearance: Acceptable
- Fillet Weld Size: 1/4"
- Fractured Root: Acceptable
- Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.1: 2015 Structural Steel Welding Code.
Approved By
Richard J DePue
Qualifications
SCWI, Test Supervisor
License
#03010018
Ben Gonzalez
Certified Welding and Testing
Certified
February 11, 2019
Welder Qualification Test Record
Qualification Type
Welder
Actual Values
Used in Weld Test
Permitted Qualifications Range
Welding Process
SMAW
SMAW
Welding Current & Polarity
DCEP
AC or DC
Welding Position
2F
1F, 2F
Welding Progression (up or down)
N/A
N/A
Weld Backing Used (grooves)
N/A
N/A
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
N/A
N/A
Plate Thickness - Fillet
1/4"
1/8" to 1/4"
Pipe Wall Thickness - Groove
N/A
N/A
Pipe Wall Thickness - Fillet
N/A
1/8" to 1/4"
Pipe Outside Diameter - Groove
N/A
N/A
Pipe Outside Diameter - Fillet
N/A
All pipe fillets
Weld deposit thickness
Single and Multi-pass
Both
Filler Metal - Specification #
AWS A5.1
AWS 5.1
Filler Metal - Classification #
E7018
E70XX, E60XX
Filler Metal - F #
F-4
F-1 to 4
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
N/A
N/A
Visual Inspection
- Acceptable: Yes
- Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Guided Bend Test
- Face Bends Acceptable: N/A
- Root Bends Acceptable: N/A
- Side Bends Acceptable: N/A
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
- Weld Appearance: N/A
- Fillet Weld Size: N/A
- Fractured Root: N/A
- Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D9.1: 2012 Sheet Metal Welding Code.
Approved By
Richard J DePue
Qualifications
SCWI, Test Supervisor
License
#03010018