Welder Qualification Test Record
Qualification Type
Welder
Actual Values
Used in Weld Test
Permitted Qualifications Range
Welding Process
SMAW
SMAW
Welding Current & Polarity
DCEP
AC or DC
Welding Position
3G, 4G
All position plate
Welding Progression (up or down)
Up
Up
Weld Backing Used (grooves)
None
With or without Backing
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
3/8"
1/8" to 3/4"
Plate Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Wall Thickness - Groove
N/A
1/8" to 3/4"
Pipe Wall Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Outside Diameter - Groove
N/A
> 24" Only
Pipe Outside Diameter - Fillet
N/A
All pipe fillets
Weld deposit thickness
1/8" per pass
1/8" Max per pass
Filler Metal - Specification #
AWS A5.1
AWS 5.1
Filler Metal - Classification #
E6010/7018
E70XX, E60XX
Filler Metal - F #
F-3/4
F-1 to 4
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
N/A
N/A
Visual Inspection
- Acceptable: Yes
- Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Guided Bend Test
- Face Bends Acceptable: Acceptable
- Root Bends Acceptable: Acceptable
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
- Weld Appearance: N/A
- Fillet Weld Size: N/A
- Fractured Root: N/A
- Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.1: 2015 Structural Steel Welding Code.
Approved By
Richard J DePue
Qualifications
SCWI, Test Supervisor
License
#03010018
Dalton Delgado
Angleton ISD
Welder Qualification Test Record
Qualification Type
Welder
Actual Values
Used in Weld Test
Permitted Qualifications Range
Welding Process
SMAW
SMAW
Welding Current & Polarity
DCEP
AC or DC
Welding Position
4G
1F,2F,4F,1G,4G
Welding Progression (up or down)
N/A
N/A
Weld Backing Used (grooves)
Yes
With backing
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
3/8"
1/8" to 3/4"
Plate Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Wall Thickness - Groove
N/A
1/8" to 3/4"
Pipe Wall Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Outside Diameter - Groove
N/A
> 24" Only
Pipe Outside Diameter - Fillet
N/A
All pipe fillets
Weld deposit thickness
1/8" per pass
1/8" Max per pass
Filler Metal - Specification #
AWS A5.1
AWS 5.1
Filler Metal - Classification #
E7018
E70XX, E60XX
Filler Metal - F #
F-4
F-1 to 4
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
N/A
N/A
Visual Inspection
- Acceptable: Yes
- Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Guided Bend Test
- Face Bends Acceptable: Acceptable
- Root Bends Acceptable: Acceptable
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
- Weld Appearance: N/A
- Fillet Weld Size: N/A
- Fractured Root: N/A
- Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.1: 2015 Structural Steel Welding Code.
Approved By
Richard J DePue
Qualifications
SCWI, Test Supervisor
License
#03010018
Dalton Delgado
Angleton ISD
Welder Qualification Test Record
Qualification Type
Welder
Actual Values
Used in Weld Test
Permitted Qualifications Range
Welding Process
SMAW
SMAW
Welding Current & Polarity
DCEP
AC or DC
Welding Position
2G,3G
1F, 2F, 3F,1G,2G,3G
Welding Progression (up or down)
Up
Up
Weld Backing Used (grooves)
Yes
With backing
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
3/8"
1/8" to 3/4"
Plate Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Wall Thickness - Groove
N/A
1/8" to 3/4"
Pipe Wall Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Outside Diameter - Groove
N/A
> 24" Only
Pipe Outside Diameter - Fillet
N/A
All pipe fillets
Filler Metal - Specification #
AWS A5.1
AWS 5.1
Filler Metal - Classification #
E7018
E70XX, E60XX
Filler Metal - F #
F-4
F-1 to 4
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
N/A
N/A
Visual Inspection
- Acceptable: Yes
- Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Guided Bend Test
- Face Bends Acceptable: Acceptable
- Root Bends Acceptable: Acceptable
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
- Weld Appearance: N/A
- Fillet Weld Size: N/A
- Fractured Root: N/A
- Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.1: 2015 Structural Steel Welding Code.
Approved By
Richard J DePue
Qualifications
SCWI, Test Supervisor
License
#03010018
Dalton Delgado
Angleton ISD
Witness
Robert Woodruff Jr.
Certified
September 10, 2018
Welder Qualification Test Record
Qualification Type
Welder
Actual Values
Used in Weld Test
Permitted Qualifications Range
Welding Process
SMAW
SMAW
Welding Current & Polarity
DCEP
AC or DC
Welding Position
1G
1F,2F,1G
Welding Progression (up or down)
N/A
N/A
Weld Backing Used (grooves)
Yes
With backing
Material Type (specification)
A-36 Steel
Any M-1 material
Plate Thickness - Groove
3/8"
1/8" to 3/4"
Plate Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Wall Thickness - Groove
N/A
1/8" to 3/4"
Pipe Wall Thickness - Fillet
N/A
1/8" to Unlimited
Pipe Outside Diameter - Groove
N/A
> 24" Only
Pipe Outside Diameter - Fillet
N/A
All pipe fillets
Filler Metal - Specification #
AWS A5.1
AWS 5.1
Filler Metal - Classification #
E7018
E70XX, E60XX
Filler Metal - F #
F-4
F-1 to 4
GTAW Electrode - Specification #
N/A
N/A
GTAW Electrode - Classification #
N/A
N/A
Shielding & Gas Composition.
N/A
N/A
Visual Inspection
- Acceptable: Yes
- Procedure: IW-VT-01, Rev. 2, 07-25-12
*Note - Visual inspection shall be in the "as welded" condition. See D1.1 and 4.81.
Guided Bend Test
- Face Bends Acceptable: Acceptable
- Root Bends Acceptable: Acceptable
*Note - Bend specimens shall have all reinforcements removed. See D1.1 and 4.30.1.
Fillet Break Test
- Weld Appearance: N/A
- Fillet Weld Size: N/A
- Fractured Root: N/A
- Cross Section: N/A
*Note - For inspection and disposition of the fractured weld root see D1.1, 4.30.2.3 and 4.30.4.1.
The herein named authority, certifies that the statements in this record are correct and that the test welds were prepared, welded, and tested in conformance with the requirements of AWS D1.1: 2015 Structural Steel Welding Code.
Approved By
Richard J DePue
Qualifications
SCWI, Test Supervisor
License
#03010018